Skip to content

The shop for professionals – business accounts, volume discounts & more

Cart

Encyclopedia

AQL (acceptable quality level) for gloves

AQL stands for acceptable quality level. For protective gloves, the value describes how many leaking gloves a production batch may statistically contain at most. The lower the AQL value, the fewer gloves with holes the batch contains.

View matching products: Disposable gloves

When is this relevant?

Relevant for disposable gloves in laboratories, medicine, food and cleaning when the glove is meant to act as a barrier against liquids and microorganisms. The AQL value helps compare data sheets but says nothing about resistance to specific chemicals.

How the AQL is tested

A sample is taken from each batch according to the rules of ISO 2859-1. The gloves are checked for holes using the air leak test and the water leak test according to DIN EN ISO 374-2:2020-04. The number of leaking gloves determines which quality level the batch meets.

AQL levels for protective gloves

  • Performance level 3: AQL below 0.65 (inspection level G1)
  • Performance level 2: AQL below 1.5 (inspection level G1)
  • Performance level 1: AQL below 4.0 (inspection level S4)

For protection against microorganisms according to EN ISO 374-5, the glove must pass the penetration test; in practice at least performance level 2 is required.

Medical disposable gloves

For medical gloves for single use, DIN EN 455-1:2022-04 specifies an AQL of no more than 1.5. Many disposable gloves meet both standards, for example the KCL Dermatril P 743 with an AQL below 0.65 according to the manufacturer.

What to look out for

  • A lower AQL value means a tighter batch, but not better protection against chemicals. For that, the type and code letters according to DIN EN ISO 374-1:2018-10 count.
  • The AQL value is stated in the data sheet or the instructions for use, not always on the packaging.
  • Change gloves immediately after damage or contact with chemicals, even with a low AQL.

Sources

  • DIN Media: DIN EN ISO 374-2:2020-04, Protective gloves, determination of resistance to penetration
  • DIN Media: DIN EN 455-1:2022-04, Medical gloves for single use, requirements and testing for freedom from holes
  • Ejendals: Overview of standards for protective gloves, AQL levels
  • Honeywell: KCL Dermatril P 743, product data (AQL below 0.65)