Special models follow their own standards, not just the S3 protection class
Specialized models are safety shoes for tasks not covered by the basic categories of EN ISO 20345. Additional standards apply: DIN EN 15090:2012-04 for firefighter shoes, DIN EN ISO 17249:2014-05 for chainsaw protection shoes, and DIN EN ISO 20349-1:2021-04 for foundry shoes. An S3 shoe does not replace them. According to the DGUV, foundry shoes must meet the basic requirements of the safety shoe standard and also provide protection against molten metal (iron or aluminum).
In our range, you will find firefighter and rescue service boots, forestry boots, foundry boots, and roofing shoes, predominantly from ELTEN. The risk assessment determines which shoe is required for which task.
The DGUV list of examples (as of March 12, 2024) specifies a foundry shoe according to DIN EN ISO 20349 Part 1 for foundry workers and a welding shoe according to Part 2 for welders. Suitable protective clothing can be found under Forestry Protection and Welding Protection. Standard models up to S3 can be found under S3 Safety Shoes.

Four applications, four standards: Which boot is right for which hazard
Four areas of use define the category. Each has its own designation:
- Fire brigade and emergency services: DIN EN 15090:2012-04 with types F1 and F2, in the range the ELTEN boots CURT II, CURTIS and FRASER Pro
- Forestry: DIN EN ISO 17249:2014-05 with protection level according to chain speed, in the range the ELTEN ARBORIST GTX with protection level 2
- Foundry: DIN EN ISO 20349-1:2021-04 with the symbols Fe and Al, in the range the ELTEN boots STAN and CALVIN
- Roofing: no specific footwear standard, but the guidelines of the DGUV example list, in the range the ELTEN models ANDERSON Roof and Loop
For roofing work, the DGUV example list specifies a safety shoe, recommends shoe shape B and points to a metallic insert against penetration. In addition, the requirement for FO should be checked, depending on the activity, a wedge sole is recommended.
HI, HRO, Fe, Al, F2A: How to read the special boot markings
The boots feature symbols that go beyond the S1 to S7 categories. According to the DGUV and the manufacturer's specifications, they mean:
- HI: Thermal insulation of the sole assembly, for firefighting boots in levels HI1 to HI3 (according to the manufacturer HAIX)
- CI: Cold insulation of the sole assembly
- HRO: Resistance to contact heat
- WR: Water resistance of the footwear
- Fe and Al: Resistance to molten iron and aluminium, respectively
- F2A and F1PA: Firefighting type with antistatic properties (A); F1PA also includes penetration resistance (P)
- Protection level 1 to 3: Protection against chainsaw cuts at chain speeds of 20, 24 or 28 m/s, respectively
The markings in the product range reflect this in practice. The CURTIS is marked "DIN EN 15090 F2A (Type 2) CI HI3 HRO WR", the ARBORIST "EN ISO 17249 S3 CI SRC, Protection level 2" and the CALVIN "EN ISO 20349-1 S3 HI HRO SRC Fe Al". The foundry standard test is carried out according to the DGUV with (360 ± 50) cm³ of molten metal, which must not penetrate to the inner surface of the footwear. Furthermore, no elements that could trap molten metal may be present in the area of the footwear.
Regarding the current standards: DIN EN 15090:2012-04 continues to apply to firefighting footwear, while a draft prEN 15090:2024 is available. DIN EN ISO 20349-1:2021-04 applies to foundry footwear, and DIN EN ISO 17249:2014-05 applies to cut protection. An overview of categories and standards can be found in Choosing the right PPE: What lies behind categories and standards, and further abbreviations in the PPE glossary.

Checkpoints before buying a specialty boot
Companies should clarify the following points before ordering:
- Standard and year of issue: Check whether the special standard is indicated on the shoe.
- Forestry: The level of protection must match the chain speed specified by the saw manufacturer.
- Firefighting: According to DIN Media, a risk assessment should indicate whether the shoes are suitable for the intended use.
- Foundry: Fe or Al must match the metal being processed.
- Orthopedics: According to the manufacturer, STAN, CALVIN, GEORGE and ARBORIST are suitable for orthopedic adjustments in accordance with DGUV Rule 112-191.
- Heat: The foundry models are rated HI and HRO. According to the manufacturer, the sole is heat-resistant up to 200 °C and can withstand temperatures of up to approximately 300 °C for short periods.
- Care: For the ANDERSON Loop, the manufacturer recommends regular cleaning with a suitable leather dressing.
- Shoe height: The risk assessment determines the required height, from ankle-high to high.
Questions about specialty boots
Is an S3 shoe sufficient in the foundry?
Is an S3 shoe sufficient in the foundry?
No. According to the DGUV, foundry shoes must meet the basic requirements of the safety footwear standard, as well as the requirements of ISO 20349-1 for protection against molten metal. The DGUV’s list of examples expressly specifies a foundry shoe according to DIN EN ISO 20349 Part 1 for foundry workers. The Fe or Al marking indicates which metal the shoe has been tested against.
What level of protection does a forestry boot need?
What level of protection does a forestry boot need?
This depends on the saw's chain speed. According to the DGUV, protection level 1 is at 20 m/s, protection level 2 at 24 m/s, and protection level 3 at 28 m/s. The saw manufacturer specifies the chain speed in the operating instructions. The pictogram indicating the protection level must be at least 30 mm by 30 mm and clearly visible on the outside of the boot.
What do F1 and F2 mean for firefighting boots?
What do F1 and F2 mean for firefighting boots?
According to the manufacturer HAIX, Type 1 is intended for outdoor use and outdoor firefighting, while Type 2 is intended for all firefighting and rescue operations requiring puncture resistance and toe protection. F2A supplements the basic requirements with antistatic properties, while F1PA adds puncture resistance and antistatic properties.
Which boot is suitable for emergency services?
Which boot is suitable for emergency services?
The DGUV example list specifies safety footwear for emergency services. According to the manufacturer, ELTEN FRASER Pro boots are marked in accordance with DIN EN 1590 as type F1PA. Whether fire service boots or safety boots are required is determined by the company’s risk assessment.
Can the sole leave marks on fresh bitumen?
Can the sole leave marks on fresh bitumen?
For working on black roofing membranes, the ELTEN ANDERSON Roof and Loop models feature a flat sole with a tread depth of approximately 2.5 mm that leaves hardly any marks in fresh bitumen, according to the manufacturer. At the same time, the soles are marked HI and HRO and can withstand short-term temperatures of up to approximately 300 °C, according to the manufacturer.
What do shapes B, C and D mean for boots?
What do shapes B, C and D mean for boots?
The standards for foot protection distinguish five shoe styles: A is the low shoe, B the low ankle boot, C the mid-height boot, D the high boot, and E the thigh-high boot. The style is indicated in the product description. The FRASER Pro Mid is style B, while the CURT II and FRASER Pro High are style C, and the CURTIS is style D. According to the DGUV, the required style is determined by the risk assessment or by more comprehensive footwear standards.
Weiterführende Links und Quellen
Quellen
- DGUV, Fachbereich PSA: Welche Anforderungen beinhalten die Kurzzeichen?
- DGUV: Häufig gestellte Fragen und Antworten zu Fußschutz
- DGUV: Beispielliste Fußschutz für ausgewählte Tätigkeiten, Stand 12.03.2024
- DGUV, Fachbereich PSA: Gießereischuhe und Schweißerschuhe, sicher ist sicher 02/2018
- DIN Media: DIN EN ISO 20349-1:2021-04, Schuhe für Gießereien
- DIN Media: DIN EN ISO 17249:2014-05, Schnittschutz gegen Kettensägen
- DIN Media: DIN EN 15090:2012-04, Schuhe für die Feuerwehr
- DIN Media: Entwurf prEN 15090:2024, Schuhe für die Feuerwehr
- HAIX: Einteilung von Feuerwehrschuhen nach DIN EN 15090 (Herstellerinformation)
Herstellerangaben zu den Modellen: Produktinformationen von ELTEN. Abgerufen am 29.10.2026.
Hinweis: Diese Seite informiert allgemein (Stand 29.10.2026). Welche Schutzausrüstung erforderlich ist, ergibt sich aus der Gefährdungsbeurteilung Ihres Unternehmens. Im Zweifel klären Sie die Auswahl mit Ihrer Fachkraft für Arbeitssicherheit.