DIN EN 16350:2014-07 defines when protective gloves are considered electrostatic dissipative. It requires a vertical resistance of less than 1.0 × 10⁸ ohms, measured according to EN 1149-2:1997 at 23 °C and 25 % relative humidity. The standard is aimed mainly at work areas with a risk of explosion.

View matching products: Work gloves

When is this relevant?

Relevant where electrostatic charge can become an ignition source, for example in potentially explosive atmospheres, or where dissipative gloves are required in ESD protected areas. The glove only dissipates charge if the wearer is grounded, for example via ESD footwear and a dissipative floor.

Requirement and testing

All parts of the glove must have a vertical resistance of less than 1.0 × 10⁸ ohms (100 megohms). Testing follows EN 1149-2:1997 on conditioned samples at an air temperature of 23 ± 1 °C and a relative humidity of 25 ± 5 %. Every single measurement must meet the limit.

What the standard does not cover

  • Mechanical protection: covered by EN 388, the values are marked separately on the glove.
  • Chemical protection: covered by DIN EN ISO 374-1:2018-10.
  • ESD protected areas in electronics manufacturing: covered by DIN EN IEC 61340-5-1:2025-06 (VDE 0300-5-1) with its own requirements for people and equipment.

What to look out for

  • Dissipation only works if the wearer is grounded, for example via ESD footwear and a dissipative floor.
  • Conformity with EN 16350 is stated in the instructions for use and the data sheet, often together with the measured resistance values for palm, back of the hand and cuff.
  • Follow the manufacturer's information on limits of use, care and service life.

Sources

  • DIN Media: DIN EN 16350:2014-07, Protective gloves, Electrostatic properties
  • DIN Media: DIN EN IEC 61340-5-1:2025-06 (VDE 0300-5-1)
  • Ejendals: EN 16350, electrostatic protection (ATEX)