ELTEN Safety Shoes: Range and Protection Classes
At A+S Technigro, you will find over 200 ELTEN models: slip-ons, lace-up boots, sandals, fire boots, and socks. The majority are safety shoes according to DIN EN ISO 20345:2024-06, especially in the S3 protection class with the S3S and S3L variants, S1P and S1PS, and S2. In addition, there are occupational shoes of classes O1 and O2 according to EN ISO 20347:2022, which do not have a toe cap, and fire boots according to DIN EN 15090:2012-04.
The vast majority of ELTEN models in the shop are additionally marked as ESD shoes. Which class and which additional requirements your employees need is determined by your company's risk assessment.

How to read the designation in the model name
For ELTEN, the model name is followed by a series of abbreviations, for example ESD S3S or GTX ESD S3S WR. They describe what has been tested and make models of the same class comparable.
What you should check before purchasing
- Protection class: S1, S1P, S1PS, S2, S3, S3S or S3L according to DIN EN ISO 20345:2024-06; O1 and O2 indicate occupational shoes without a toe cap.
- Penetration protection: S3 without an additional letter has a metal insert, S3S and S3L have a non-metallic one. S3S is tested with the 3.0 mm test nail, S3L with the 4.5 mm test nail.
- Water protection: S2 and S3 are tested for water penetration and water absorption of the upper material. A shoe is only permanently waterproof with the WR designation.
- ESD: important in electronics manufacturing and in ESD protection zones; the dissipation only works via a suitable floor.
- Cold: CI stands for cold insulation of the sole construction, for example in winter and outdoor models.
Where ELTEN goes beyond the basic classes
In addition to safety shoes for indoor use, warehouses and construction sites, ELTEN offers models for applications with special requirements. The main categories in the range are:
- Fire brigade and emergency services: Boots such as COLIN II, CRAIG or CRUZ are rated F2A according to DIN EN 15090:2012-04, meaning they are Type 2 with toe and penetration protection and antistatic properties. The Fraser Pro emergency service boots are marked F1PA. HI3 indicates the thermal insulation of the sole construction at 250 °C for 40 minutes. You can find more models under Special Models.
- Wet conditions: Models with a GORE-TEX membrane carry GTX in the name. The WR marking is the key indicator of permanent waterproofness, but not every GTX model has it; the glossary explains the abbreviations under Additional Markings.
- Electronics and ESD protection zones: DIN EN IEC 61340-5-1:2025-06 applies to ESD protection zones. The glossary explains what distinguishes ESD shoes from antistatic shoes under ESD Shoes.
- Dry indoor areas: Safety sandals of classes S1 and S1PS, as well as O1 and O2 occupational shoes for workplaces where the risk assessment permits open or lightweight footwear.
- Accessories: You can find ELTEN socks under Socks and Accessories.
Even within a class, models differ in terms of fastening, width and additional requirements. Therefore, compare the full marking, not just the protection class.

Filter by workplace
For initial guidance, consider the floor, wet conditions, and surroundings:
- Halls, warehouses, industrial environments: S1PS or S3S safety shoes, with ESD if required.
- Construction sites and outdoor areas: S3S safety boots, with WR for persistently wet conditions.
- Electronics manufacturing: ESD models used in conjunction with a conductive floor.
- Cold environments: Models marked CI.
For businesses with larger requirements, B2B registration is worthwhile for individual terms and conditions.
Questions about ELTEN safety shoes
Are ELTEN models with GTX permanently waterproof?
Are ELTEN models with GTX permanently waterproof?
GTX stands for a GORE-TEX membrane. Whether the entire shoe has been tested for waterproofness is indicated by the WR designation according to DIN EN ISO 20345:2024-06. Not all GTX models in the range carry this designation, so please check for the full designation in the model name.
Which ELTEN boots are suitable for the fire department?
Which ELTEN boots are suitable for the fire department?
Type 2 according to DIN EN 15090:2012-04 is intended for firefighting and rescue operations where toe and puncture protection are required; F2A stands for Type 2 with antistatic properties. Examples in our range include the COLIN II, CRAIG, CRUZ and CLAY. The version your fire department needs depends on the risk assessment.
Do ESD shoes require a special floor?
Do ESD shoes require a special floor?
Yes. An ESD shoe only safely dissipates electrostatic charges if the person, shoe, and floor together form a tested system. The requirements for ESD protection zones are set out in DIN EN IEC 61340-5-1:2025-06.
What is the difference between S3S and S3L?
What is the difference between S3S and S3L?
Both have non-metallic puncture protection. S3S is tested with a 3.0 mm test nail, S3L with a 4.5 mm test nail. Find out more in the encyclopedia under Puncture protection.
What is jori by ELTEN?
What is jori by ELTEN?
We carry jori by ELTEN in our shop as our own brand. You can find all the models under jori by ELTEN.
Can I wear safety sandals?
Can I wear safety sandals?
Safety sandals rated S1 and S1PS have a toe cap but are open. Whether they are permitted is determined by the risk assessment; in wet conditions or for outdoor work, closed shoes rated S2 or S3 are generally more suitable.
Weiterführende Links und Quellen
Quellen
- DIN Media: DIN EN ISO 20345:2024-06, Sicherheitsschuhe (abgerufen am 15.11.2026)
- DIN Media: DIN EN 15090:2012-04, Schuhe für die Feuerwehr (abgerufen am 15.11.2026)
- DIN Media: DIN EN IEC 61340-5-1:2025-06 (VDE 0300-5-1) (abgerufen am 15.11.2026)
- HAIX: Normen für Feuerwehrschuhe nach DIN EN 15090 (abgerufen am 15.11.2026)
- Herstellerangaben ELTEN in den Produktdaten (abgerufen am 15.11.2026)
Die Auswahl der Schutzausrüstung richtet sich nach der Gefährdungsbeurteilung Ihres Unternehmens.


